930A -
Arbiter Systems, Inc.
Model 930A Three Phase Power Analyzer is an economical alternative to the Model 931A Power System Analyzer when the dc voltage measurement, transducer calibration and timer features are not required. The Model 930A has the same ac accuracy as the Model 931A with PowerDSA™ Digital Signal Analysis. Basic accuracy of 0.05 % of reading and 0.05 ° phase, harmonic analysis, and full three-phase capability are standard.
-
Extech 380405 -
Extech Instruments Corporation
Capacitance box with 5 decade ranges of capacitance - The Extech 380405 Capacitance Decade Box is very popular for product design testing and calibration because it can be substituted into a circuit and function in the place of any component with a standard value easily. Alternatively, it can be used to identify the best value for circuit operation then read that value from the switches. A capacitor of the size indicated by the decade box switches can then be put into the circuit.
-
1105 ER -
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● In addition to facilitating for precision measurement, test leads for simplified two-wire measuring system also are supplied as standard accessories.● Battery operated.● Battery life indicator. ● Calibration performed with supplied test leads.
-
4105 ER -
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● In addition to facilitating for precision measurement, test leads for simplified two-wire measuring system also are supplied as standard accessories.● Battery operated.● Battery life indicator. ● Calibration performed with supplied test leads.
-
2105 ER -
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● In addition to facilitating for precision measurement, test leads for simplified two-wire measuring system also are supplied as standard accessories.● Battery operated.● Battery life indicator. ● Calibration performed with supplied test leads.
-
1805 ER -
Standard Electric Works Co., Ltd
● High quality Taut Band movement.● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● Test test leads are supplied as standard accessories for simplified two-wire measuring system.● Battery operated.● Battery check function.● Calibration performed with supplied test leads.
-
2120 ER -
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● The test leads are supplied as standard accessories for simplified two-wire measuring system.● 0Ω adjustment.● Battery operated.● Data hold function.● Low battery indication.● Calibration performed with supplied test leads.
-
2705 ER -
Standard Electric Works Co., Ltd
● High quality Taut Band movement.● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● The test leads are supplied as standard accessories for simplified two-wire measuring system.● Battery operated.● Battery check function.● Calibration performed with supplied test leads.
-
ONYX Apps
Oscilloscope for iOS is great for analyzing audio range signals, or learning oscilloscope measurement basics. The interface includes many standard oscilloscope controls, such as: triggering, time and voltage per division, signal measurement cursors, and more. The app incorporates a signal (function) generator capable of generating sine, square, triangle, and sawtooth waveforms of up to 22 KHz. Calibration to an external reference signal is supported, guaranteeing the accuracy of measurements.
-
Keighley Laboratories LTD
Performing chemical analysis of metal alloys including both ferrous and non-ferrous alloys.Chemical analysis involves determining the chemical constituents of metals and related materials.An industry leader and co-operating laboratory for qualifying Calibration Standards for Chemical Analysis.Our chemical laboratory processes include Spectroscopy – Optical Emission Inductively Coupled Plasma, gas analysers, wet chemical, Intercrystalline/ Intergranular Corrosion (including G28, G48 etc).
-
Applied Image, Inc.
The SM Series of Stage Micrometer Calibration Standards is ideally suited for calibrating optical, imaging, video as well as reticle based measurement systems. Designed for ease of use and manufactured for durability, the SM Series has both English and Metric scales in one or two axis configurations. Our SM series covers a range of low to high power systems, and can always be custom manufactured to perfectly fit your needs.
-
UltrapenX2™ PTBT4 -
Myron L Company
*Accuracy of up to ±0.3 ppm FCE*Calibration with pH and ORP Standard Solutions*Automatic Temperature Compensation*Measurement Storage with Time, Date and Location*Export Stored Measurement Data Via Email*Live or Hold Mode – User Selectable*Proprietary Sensor Design*Rugged Design with Aircraft Aluminum Body*Durable, Epoxy Encapsulated Electronics*Waterproof*Powered by One N Type Battery (Included)
-
HFM-301 / HFC-303 -
Teledyne OEM Solutions
The HFM-301 / HFC-303 meters and controllers have flow ranges from 0-25 slm to flows of 0-1000 slm; provide analog outputs, are constructed of stainless steel and have normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. With a choice of elastomers and high pressure options, the HFM-301 / HFC-303 services a wide variety of applications. Cleaning for oxygen service is available.
-
AQMS-1000 -
Focused Photonics Inc.
FPI’s ambient air monitoring system consists of a sampling subsystem, a gas dynamic calibration subsystem, a meteorological parameters monitoring subsystem, a standard parameters monitoring subsystem, and a data acquisition and processing subsystem. It can monitor conventional air pollutants such as SO2, NO, NOX, CO, O3, PM2.5, PM10, etc. FPI also provides compact AQMS, micro AQMS, and mobile stations applicable to various customer needs.
-
Brighton Electronics
Strong Anodized NEMA4X-IP56 ALUMINUM 1/8 DIN CASE Compact Design Provides Excitation to Transducers or Sensors Accept DC mV/V, V, mA Signal Proportional Analog Output V or mA Easy to Program using 4 ButtonsFront Panel Shunt Calibration User Programmable High & Low Set Point Standard No-Output or Relay Output Optional 8-Step Output, RS232, or BCD Output Available